Use realistic practice, code-book drills, and calculations until weak topics become strengths.
0of 20 today
Resume Session
0DAY STREAK
0ANSWERED
—ACCURACY
—READINESS
Quick start
Study tools
Best daily routine
Complete your question goal, do five timed code lookups, then review missed questions or flashcards. Use the full exam after your topic accuracy is consistently above 70%.
Recommended Next Drill
Topic Mastery
Weakest areas
Readiness combines overall accuracy, topic coverage, and best exam score. Treat it as a study indicator, not a guarantee of passing.
Achievements
App update check
If Cloudflare shows Version 1.0.1 but your Home Screen app still looks old, use the button below once.
After uploading a new version: open the site in Safari, refresh once, then fully close and reopen the Home Screen app.
Build a session
Your active session is saved automatically on this device. The simulator uses a 70% practice benchmark. It is not an official DSPS exam and does not contain confidential exam questions.
QUESTION
ANSWERED
FLAGGED
TIME LEFT
Confidence:
Electrical Calculators
Formula Guide
Ohm's law: I = V ÷ R, V = I × R, R = V ÷ I Single-phase: VA = V × I Three-phase: VA = 1.732 × V × I Three-phase real power: W = 1.732 × V × I × PF Voltage drop %: drop ÷ system voltage × 100 Continuous load: 125% continuous + 100% noncontinuous
Practice tools versus exam calculator
The electrical calculators below are study tools. During a simulated test, the on-screen calculator is intentionally limited to a conservative nonprogrammable standalone style. Wisconsin DSPS states that programmable calculators and cell-phone calculators are not allowed.
Ohm's Law
20 A
I = V ÷ R
Three-Phase Current
208.2 A
I = VA ÷ (1.732 × V)
Voltage Drop Percentage
3%
% drop = drop ÷ system voltage × 100
Continuous Load Sizing
136 A
125% continuous + 100% noncontinuous
Motor Feeder Ampacity
94 A
125% largest motor + all other motor loads
Box-Fill Volume
18 cu in
Training calculator; verify actual conductor and clamp counts with NEC 314.16.
Single-Phase Current
50 A
I = VA ÷ V
Three-Phase kW
20 kW
kW = 1.732 × V × I × PF ÷ 1000
Conduit Fill Percentage
40%
Verify allowable percentage and actual areas using NEC Chapter 9 tables.
Ampacity Adjustment
80 A
Adjusted ampacity = base ampacity × factor.
Transformer kVA
44.9 kVA
Demand Load
37,500 VA
Parallel Conductors
200 A
Power Factor Correction Study
55.3 kVAR
Apparent Power
24.9 kVA
Voltage Drop from Resistance
6 V
Vdrop = I × R
Efficiency
85%
Three-Phase Current from kW
133.6 A
Single-Phase kVA
12 kVA
Feeder Continuous Load
102 A
Motor Feeder
113 A
Series Resistance
20 Ω
Parallel Resistance
6.67 Ω
Horsepower to Watts
7,460 W
Study conversion: 1 hp ≈ 746 W.
Watts to Current
20.83 A
Voltage-Drop Percentage
3%
Current from Three-Phase kVA
208.2 A
Current from Single-Phase kVA
50 A
Percent Change
25%
Current per Parallel Set
200 A
Code Lookup Trainer
NEC Article Explorer
Search the reference index
Search a topic, article, table, or Wisconsin rule. Tap Open Reference to record the lookup in your study plan.
Timed Lookup Drill
0 completed
The app gives you a topic. Decide where you would look in your permitted code book, then choose the reference. This records accuracy and lookup time.
Recently opened
No references opened yet.
What counts as a lookup?
Home counter updates immediately
Opening a search result or answering a timed lookup drill counts toward today’s lookup goal. Typing in the search box by itself does not count.
Flashcards
Formula & Reference Sheet
These are study formulas and navigation aids. Confirm code requirements, table values, exceptions, and Wisconsin amendments in your permitted references.
Your Progress
0TOTAL ANSWERED
—ACCURACY
—READINESS
0mSTUDY TIME
Speed
Difficulty Performance
Flashcard Performance
Code Lookup Performance
Confidence breakdown
Topic performance
Review Center
Recent Sessions
Backup Progress
Save your progress as a small text file before changing phones or clearing browser data.
Adaptive Study Settings
Today
Daily Study Plan
Daily goal
Exam-Style Calculator
Nonprogrammable standalone-style practice
Memory: 0
This intentionally omits formula presets, graphing, stored programs, equation solving, history, and internet features.
Enter constants such as 1.732 manually.